KAS-Keyless Access Security

            Lift Call

            Reader:

            The following readers can be used for Lift Call:

            • Standard Access Control Reader
            • Bluetooth Access Control Reader (mobile phone can call the lift)

             

            Wiring:

            Installation:

            • Install the Access Control relay contacts (NO, NC, COM) on the lift button signals.
            • Swipe a card on the access control reader then all of the lift buttons will be active.
            • The Access Control relay contacts can be wired to call the lift.
            • Usually, installed on the ground floor/lobby only
            • No lift control module required!
            • Wiring is specific to each lift. Contact us if you need assistance.

             

            Programming:

            • Swipe System Card -> Green LED -> If Red LED, swipe system card again, or press RST switch on circuit board.
            • Swipe Parameter Card -> Green LED
            • Test by swiping Master Card -> Green LED -> Relay will fire and close the circuit to the lift buttons ready for switching.

             


            Updated: 07 Jul 2019 09:52 AM
            Helpful?  
            Help us to make this article better
            0 0