Lift Call

Lift Call

Reader:

The following readers can be used for Lift Call:

  • Standard Access Control Reader
  • Bluetooth Access Control Reader (mobile phone can call the lift)

 

Wiring:

Installation:

  • Install the Access Control relay contacts (NO, NC, COM) on the lift button signals.
  • Swipe a card on the access control reader then all of the lift buttons will be active.
  • The Access Control relay contacts can be wired to call the lift.
  • Usually, installed on the ground floor/lobby only
  • No lift control module required!
  • Wiring is specific to each lift. Contact us if you need assistance.

 

Programming:

  • Swipe System Card -> Green LED -> If Red LED, swipe system card again, or press RST switch on circuit board.
  • Swipe Parameter Card -> Green LED
  • Test by swiping Master Card -> Green LED -> Relay will fire and close the circuit to the lift buttons ready for switching.

 


    • Related Articles

    • Lock-S Lift Control

      Designate card access to assigned floors Specifications  Wiring Diagram ​ Function Guest cards can only access the permitted floors by swiping the card. Example: If the room is on the third floor, the guest can only reach the third floor. When ...
    • LMS Lift Control Module - Manual

      Introduction Used in conjunction with the LMS-Software & the LMS-Access Control System The lift control system is used to control the floors the use can access This control can be pre configured and selectable options at the time of checkinn Example ...
    • Changing Lift Floor Control - With the Lift Running Card

      Function This function allows you to control the floors a staff or guest has access to. Free Floor  *This is noted in the software as Pink Box Allows any lift user access to the floor. eg Ground Floor and/or Basement etc Controlled Floors *This is ...
    • Lock-S Relay Module RM - Wiring and Programming Lift Controller RM

      This document is intended for Electrical Installers only.  Information contained herein is intended as a guide for suitably qualified Lift Controller Installers.  The ACR should be wired to the RM with the ACR Brown wire connected to the RM RS485 A+ ...
    • LMS Software - User Manual

      Full User Manual and Quick Reference Guide