Reading Error Code with Mobile Programmer V1

Reading Error Code with Mobile Programmer V1

Collect the data

Take the mobile programmer to the lock you wish to collect the records from
      1)      Press FUN x 2 *The programmer will display collect recorders
      2)      Press RUN
      3)      Hold to lock induction area, you might have to adjust the position of the mobile programmer for the best alignment of IR (infrared) readers to successful download.
      4)      It will retrieve the last 512 unlocking records. (the Mobile Programmer will count up consecutively during this time)
      5)      Wait until you see confirmation message, and 1 long beep is heard

View the Data

The following five stats can be achieved:
  1. Battery Voltage Check
  2. Date Time Check
  3. Room Identification Data
  4. Error Diagnosis Code
  5. Audit History
  1. Press FUN x 2 *The programmer 
    1. Screen will display






Check Error Code
  1. Immediately after pressing FUN x 2, Press the number 2
  2.  Review Fault Codes
Error Code 
Door Data Error Messages 
 Definition
 0
Card Number Error 
The wrong card was used i.e. 112 room card used on 202 Lock 
 1
Code Invalid 
Card has been issued over i.e. ISSUE card not additional card has been used 
2
Time limited <END> 
The card is expired or blank 
3
Locks on the other side 
Privacy latch is engaged 
4
Start Time Error 
Check the time clock on lock
5
Unlock period time error 
Check period of time on key. Download door data and re-program lock 
6
Card invalid 
Valid card has been stopped by limit card 
7
Data in card 
Card with wrong MCSC/Lock with wrong MCSC 
8
Emergency administrator error 
Issue the emergency administrator card again, or the door lock never unlock with the guest key. 
9
Card key can’t unlock VIP room 
The card key just can only unlock the guest room, without the VIP function 
P
No Error 
Valid card used. No error registered