The spindle may have been dislodged from the lock face.

Cause

  • Incorrect installation
  • a hard hit could knock the spindle lose if the door thickness is too large and the back handle in not packed out to support the spring


Indications

  • The internal handle will still unlock and open the door.
  • Mechanical Key will not unlock the lock
  • The external handle will emit the correct notifications including;
    • light flashes
    • beeps/sounds
    • motor/buzz noise

Solution

  • Remove the back handle
    • remove the batteries and the screw behind them
    • remove the 2 screws at the base of the back handle
    • slowly lift the back handle
  • Make sure the spindle is lodged into the clutch in the front handle.
    • the spring should be facing the battery side
    • *If you have a thicker door, try packing out the internal handle to the spindle has less movement in this space.
  • Put the back handle on the lock and screw in the 3 screws that were removed



    • Related Articles

    • Lock-S Manual / User Guide

      KAS Lock-S Hotel Card Lock Software Module Introduction The KAS Lock-S Software must be activated with Serial number and Product ID. The authorized client must safeguard the unique Product ID assigned. An authorized person should be assigned to take ...
    • ETouch Lock - Program/Delete Master Programming Code

      How to Program master programming code This is the highest authority and has the ability to open the lock and change/remove any other pin code, card, FOB or remote.  It can only be altered by completing the following step or completing a FACTORY ...
    • ETouch Lock - Program or Delete an RFID Card/FOB

      How to Add a RFID key card or FOB Conduct the following steps to enrol RFID key cards or FOBs to the lock.  You can enrol up to 80 RFID keycards or FOBs.  Assume master programming code is default: 123123. If you do not need to replace individual ...
    • Lock-S Software Neo - Factory Reset

      These Instructions are only for the Neo Lock when managed from the Lock-S software. Please revisit the knowledge base if you are looking for instructions on the Standalone/ Cloud-managed Neo Lock By System Card - Hotel mode only you cannot use the ...
    • Reading Error Code with Mobile Programmer V1

      Collect the data Take the mobile programmer to the lock you wish to collect the records from 1) Press FUN x 2 *The programmer will display collect recorders 2) Press RUN 3) Hold to lock induction area, you might have to adjust the position of the ...